Service Telephone£º021-64820099 24-Hour Service Hotline£º15900706965 Mail:info@jichuan.sh.cn
 Meguin
   
 
Meguin
 
 
 

 

 

 

 

 

Your present location:HomePage-Products Centre--Meguin
 
 

Megol Getriebeoel CLP 320

Gear oil CLP 320 is an EP lubricant offering excellent lubrication and wear-prevention properties.
Made of high quality base oils and the latest sulphur phosphorus additives. Suitable for use in
industrial gearboxes, roller and plain bearings that are exposed to high loads, and in particular
also for large systems with circulation lubrication systems.

Approvals / Specifications:

Lubricating oil DIN 51517 - CLP 320
Lubricating oil CLP 320 SEB 181 226

Characteristic data

 

 

approx. values

ISO viscosity class

DIN 51519

¡¡

VG320

Viscosity at 0¡ãC

DIN 51562

mm2/s

10000

Viscosity at 40¡ãC

DIN 51562

mm2/s

320

Viscosity at 100¡ãC

DIN 51562

mm2/s

24.4

Viscosity index

DIN ISO 2909

¡¡

97

Density at 15¡ãC

DIN 51757

kg/m3

910

Flash point

DIN ISO 2592

¡ãC

244

Pour point

DIN ISO 3016

¡ãC

-20

Air separation capacity / 50¡ãC

DIN 51381

min.

30

De-emulsifying capacity / 54¡ãC

DIN 51599

min.

15

Ash, oxide

DIN EN 7

g/100 g

0.03

Ash, sulphate

Din 51759

g/100 g

0.04

Content of asphaltenes

DIN 51595

g/100 g

m.n.n.*)

Content of undissolved substances

DIN 51592

g/100 g

m.n.n.*)

Water content

DIN ISO 3733

g/100 g

m.n.n.*)

Neutralisation index, acid

DIN 51558 Part 1

mg KOH/g

0.5

Corrosive effect on steel

DIN 51585

degree of corrosion

0-B

Corrosive effect on copper

DIN 51759

degree of corrosion

1-125 A3

Ageing properties

¡¡

¡¡

¡¡

Increase of viscosity

DIN 51586

%

1.8

Precipitate number

DIN 51586

ml

<0.05

Neutralisation index after 1000 h

DIN 51587

mg KOH/g

<2.0

Timken test

SEB 181302

 

 

Wear under a load of

 

 

 

43lbs after 10 min

 

mg

<4.0

Accepted load

 

lbs

60

Foaming properties

DIN 51566

¡¡

S1B-0/0

 

 

 

S2B-0/0

¡¡

 

 

S3B-0/0

Properties against sealing material

¡¡

¡¡

¡¡

SRE-NBR 1 pursuant to

¡¡

¡¡

¡¡

DIN 53538 Part 3 after

Change in volume

%-by-vol.

+5

7 days at 100¡ãC

Change in hardness

Shore

-2

FZG-gear test, short

 

 

 

Normal-test A/16,6/90

DIN 51354 part 2

 

 

 

Failure load level

 

>12

 

Unit weight change

mg/KWh

<0,27

*) m.n.n. = Quantity not detectable

¡¡

¡¡

¡¡

 
 
   
Copyright © 2001-2010 All Rights Reserved ShangHai PingYiao Trading Co.,Ltd
TEL:(86)21 6482 0099¡¡FAX:(86)21 6451 3829 Service Hotline£º15900706965£¨24-hour£©Mail:info@jichuan.sh.cn